|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
|
|
Starter Components >
Universal Parts
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch Internal, Plunger Internal, Thread type mm, Thread size 6, Remarks This solenoid can switch off the pull coil, and no external 'control' is necessary., A/pull 17, A/hold 0.25, Pull rating 40N at 25.4 mm, Hold rating 89N, Return spring 17N
|
|
Electrical Parts & Engine Management >
Solenoids
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch External, Plunger Internal, Thread type Inches, Thread size 0.25, Remarks This solenoid can´t switch off by itself, it will have to be controlled externally., Servicing Perkins, A/pull 36.5, A/hold 0.49
|
|
Starter Components >
Universal Parts
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch External, Plunger Internal, Thread type Inches, Thread size 0.158, Remarks This solenoid can´t switch off by itself, it will have to be controlled externally., Servicing Yanmar Motors, A/pull 36.5, A/hold 0.49
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm, Mount. holes 2, Mount. hole dist. 1 44.5, Thread type/inlet M12x1, Thread type/outlet M12x1, Servicing Vetus, Volvo Penta
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Servicing Stanadyne DB2
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Servicing CAV Minimec
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm, Servicing Cummins
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Plunger, Servicing Cummins
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm, Servicing Kubota Industry
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm
|
|
Electrical Parts & Engine Management >
Solenoids
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch Internal, Plunger Internal, Thread type Inches, Thread size 0.155, Remarks This solenoid can switch off the pull coil, and no external 'control' is necessary., Servicing Kubota 5 series, A/pull 36.5, A/hold 0.49
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Servicing Talbot
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Servicing Citroen, Peugeot
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Servicing CAV Epic, Lucas Epic
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Plunger
|
|
Electrical Parts & Engine Management >
Filters & Filter Parts
, Automotive >
Electrical Parts & Engine Management
Universal Yes, Manufacturer: CAV, Hand pump Yes, Thread/mm/" M14-1.5
|
|
Electrical Parts & Engine Management >
Solenoids
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch Internal, Plunger Internal, Remarks This solenoid can switch off the pull coil, and no external 'control' is necessary., A/pull 37, A/hold 0.65, Pull rating 98N at 32.00 mm, Hold rating 245N, Return spring 45N
|
|
Electrical Parts & Engine Management >
Filters & Filter Parts
, Automotive >
Electrical Parts & Engine Management
Manufacturer: CAV, Thread/mm/" M14-1.5, Servicing HC-CARGO 090345
|
|
Electrical Parts & Engine Management >
Filters & Filter Parts
, Automotive >
Electrical Parts & Engine Management
Manufacturer: CAV, Thread/mm/" 1/2"-20 UNF, Servicing HC-CARGO 090346
|
|
Electrical Parts & Engine Management >
Diesel Parts
, Automotive >
Electrical Parts & Engine Management
Type Diaphragm
|
|
Starter Components >
Universal Parts
, Automotive >
Electrical Parts & Engine Management
, Automotive >
Starter Components
, Agriculture >
Electrical Parts & Engine Management
Voltage: 12, Switch Internal, Plunger Internal, Remarks This solenoid can switch off the pull coil, and no external 'control' is necessary., Servicing Sisu Diesel 8366 40253, A/pull 46.5, A/hold 1.1, Pull rating 89N, Hold rating 178N
|